Select 90C-D2

Low Alloy / Metal Cored / Gas Shielded


Features

  • Designed for welding certain high strength, low alloy (HSLA)steels where a minimum tensile strength of 90 ksi is required.
  • Can be used in place of ER90S-D2 solid wire, resulting in less sensitivity to subsurface porosity, elmination of lack of fusion (“cold lap”), and increased travel speeds.
  • Can be used to weld pressure vessel steels such as ASTM A 302 Gr B, and castings such as A49, A291, and A735.

Standard Diameters

in (mm)
  • 0.035 (0.9)
  • 0.045 (1.2)
  • 0.052 (1.3)
  • 1/16 (1.6)

Welding Positions

Flat and Horizontal

Shielding

  • 75% Ar / 25% CO₂
  • 98% Ar / 2% CO₂
    Flow Rate: 40 – 50 CFM

Polarity

Direct Current Electrode Positive (DCEP)

Conformances

  • AWS A5.28
    • E90C-D2
  • TYPICAL WELD DEPOSIT CHEMISTRY (WT%)
    Shielding Gas C Cu Mn Mo P S Si V
    98% Ar/2% CO₂ 0.07 0.06 1.41 0.46 0.011 0.012 0.48 0.005
    Typical Mechanical Properties
    Shielding Gas Tensile Strength
    ksi (MPa)
    Yield Strength
    ksi (MPa)
    Elongation
    (%)
    WeldCondition PWHTTemp Charpy V-Notch
    -20 °F ft⋅lb (-29 °C J)
    75%Ar / 25%CO2 100 (690) 88 (608) 25.0 As-Welded 40 (54)
    98%Ar / 2%CO2 106 (728) 97 (669) 23.4 As-Welded 41 (56)

    Packaging (lbs (kg))

    33 (15) Spools, 60 (27.2) Coils, 500 (226.8) Round Drum, 800 (362.9) Hex Drum, 900 (408.2) Hex Drum

    *Some packaging options may not be available depending on diameter and product. Special package options may be available upon request.